Warning: Declaration of action_plugin_denyactions::register(Doku_Event_Handler &$controller) should be compatible with DokuWiki_Action_Plugin::register(Doku_Event_Handler $controller) in /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/denyactions/action.php on line 40

Warning: Declaration of action_plugin_tagfilter::register(&$controller) should be compatible with DokuWiki_Action_Plugin::register(Doku_Event_Handler $controller) in /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/tagfilter/action.php on line 60

Warning: Cannot modify header information - headers already sent by (output started at /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/denyactions/action.php:40) in /homepages/7/d191477725/htdocs/e-cigarette-research/inc/auth.php on line 430

Warning: Use of undefined constant wrap - assumed 'wrap' (this will throw an Error in a future version of PHP) in /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/ckgedit/action/meta.php on line 649

Warning: Cannot modify header information - headers already sent by (output started at /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/denyactions/action.php:40) in /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/ckgedit/action/meta.php on line 669

Warning: Cannot modify header information - headers already sent by (output started at /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/denyactions/action.php:40) in /homepages/7/d191477725/htdocs/e-cigarette-research/inc/actions.php on line 38

Warning: Cannot modify header information - headers already sent by (output started at /homepages/7/d191477725/htdocs/e-cigarette-research/lib/plugins/denyactions/action.php:40) in /homepages/7/d191477725/htdocs/e-cigarette-research/lib/tpl/dokuwiki/main.php on line 12
Nicotine absorption from electronic cigarette use: comparison between first and new-generation devices [E-Cigarette Research]
research:documents:r8u3bmr7

Nicotine absorption from electronic cigarette use: comparison between first and new-generation devices

Journal Article 1)

A wide range of electronic cigarette (EC) devices, from small cigarette-like (first-generation) to new-generation high-capacity batteries with electronic circuits that provide high energy to a refillable atomizer, are available for smokers to substitute smoking.

Nicotine delivery to the bloodstream is important in determining the addictiveness of ECs, but also their efficacy as smoking substitutes.

In this study, plasma nicotine levels were measured in experienced users using a first- vs. new-generation EC device for 1 hour with an 18 mg/ml nicotine-containing liquid.

Plasma nicotine levels were higher by 35–72% when using the new- compared to the first-generation device. Compared to smoking one tobacco cigarette, the EC devices and liquid used in this study delivered one-third to one-fourth the amount of nicotine after 5 minutes of use.

New-generation EC devices were more efficient in nicotine delivery, but still delivered nicotine much slower compared to tobacco cigarettes. The use of 18 mg/ml nicotine-concentration liquid probably compromises ECs' effectiveness as smoking substitutes; this study supports the need for higher levels of nicotine-containing liquids (approximately 50 mg/ml) in order to deliver nicotine more effectively and approach the nicotine-delivery profile of tobacco cigarettes.


z-ref: r8u3bmr7

1)
Farsalinos , et al. (2014), Nicotine absorption from electronic cigarette use: comparison between first and new-generation devices, http://www.nature.com/srep/2014/140226/srep04133/full/srep04133.html accessed: 2014-03-01